Product Details:
Acquisition(Max) | 8.1 kW |
Measures Technics to Minimize Ionizing Radiation Exposure | Yes |
End of Life Concept | Yes |
Recycling Information | Yes |
Brand | Siemens |
Standby Power Consumption | 2.9 kW |
Full Load | 6.75 kW |
Maximum Load | 80 kW |
Possible Type of Cooling | Water Cooling |
Minimization Compared to the Limit Value for Users | Yes |
Complete Switch-Off is Possible | No |
Size of the Surface to be Cleaned | Approx 5 m2 |
Heat Emissions Load | 3 kW |
Allowed Relative Humidity | 20 % to 75 % |
List of Hazardous Substances (not Contained in the Device) | Yes |
Allowed Ambient Temperature | 15 Deg C to 30 Deg C |
Power On Time | Ca 4 Min |
Power Off Time | Ca 1.5 Time |
Interface For Heat Recovery | No |
Device is Adjustable for the User in Terms of Height | Yes |
Uniform Operating Symbols for Device Families | Yes |
UPS Battery | 12 Months |
Model Name | Artis Zee |
Product Details:
Usage/Application | Cardiovascular Diseases |
Brand | Philips |
Model Name | Allura FC |
Lead Glass | 2x3 Feet |
Connectivity | DICOM 3.0 |
Mount Type | Floor Mount |
Generator Power | 80 kW |
Product Details:
Model Name/Number | Allura Xper FD10 |
Brand | Philips |
Programmable Positions | Standard Two Positions |
Longitudinal Float | 120 cm (47.2 inch) |
Rotation Range | 350 Degree |
Pivot Range | - 90 Deg C to 180 Deg C |
Tabletop Material | Radio Translucent Carbon Fiber Tabletop |
Tabletop Length | 319 cm (125.6 inch) |
Source Image Distance | 86.5 - 123 cm (34.1 to 48.4 inch) |
G Stand Depth | 105 cm (41.3 inch) |
Transversal Float | 36 cm (14.2 inch) |
Iso Center to Floor | FD10 Ceiling and Floor is 106.5 cm (41.9 inch) |
Focal Spot to Iso Center | Upto 76.5 cm (30.1 inch) |
Iso Centric Cradle | Yes |
Product Details:
Brand | Philips |
Model Name/Number | Allura Xper FD10/10 |
Isocenter to Floor Distance | 106.5 cm (41.9 in.) |
Focal Spot to Flat Detector | 87.5-130.3 cm, Manual and Motorized Movement |
Isocenter to Floor | 106.5 cm |
Motor Driven Rotation | 0 Deg LAO to 90 Deg LAO |
Rotation Speed | 8 Deg /Second |
Depth of G Arm | 105 cm (41,3 in.) |
Nominal Ceiling Height | 290 cm |
Focal Spot to Iso Center | 76 .5 cm |
Product Details:
Automation Mode | Motorized |
Table Top Intended Issue | Cardiac |
Radiographic X Ray Generator | 60-120 kW |
Type(Configuration) | Single Plane, Flatpanel System |
Fluoroscopic (X-Ray Generator) | 60-120 kV |
Cranial to Caudal Angulation, Deg (PA Gantry) | +- 55 to +- 55 |
Model Name | Innova 2000 |
Room Size (Feet) | 4.8 x 6.4 (16 x 21) |
Heat Storage Capacity, hu (X-Ray Tube) | 3100000 |
Cooling Method (X Ray Tube) | Oil/ H20 Closed Loop |
Radiographic Timer (X-Ray Generator) | Controlled by AutoEx Software |
Radiographic ma (X-Ray Generator) | 10-1250 |
Product Details:
Table Rotation | +/- 180 Degree |
Nominal Output Power | 100 kW |
Offset C-Arm (Pivot) Permits | 117 Degree/+105 Degree RAO/LAO Rotation |
Transverse Travel | Manual +/- 14 cm (+/- 5.5 in) |
Vertical Travel | 30 cm (12 in) |
Model Name | GE Innova 2100 |
Longitudinal Travel | 110 cm (43.3 in) |
Visibility Range | 4 cm - 13 cm (Using 20 cm PMMA and 16 cm PMMA Step Wedge) |
Range of Frequency | 20 kHz - 60 kHz |
L-Arm Rotates on its Vertical Axis | +/- 100 Degree (+/- 95 Degree motorized limit set) |